Documentation

HTTP monitoring

Monitor the availability of a website or API without storing its response body.

Create an HTTP monitor

  1. Open Monitors, select Add monitor, and choose HTTP endpoint.
  2. Enter a Name and the public URL to check, including https:// or http://.
  3. Choose Method and Interval. Use GET for a normal request, or HEAD if your endpoint supports it.
  4. Open Advanced settings to change the expected status, timeout, or optional latency threshold, or to supply a secret header name and value.
  5. Select Save monitor. The first check is scheduled immediately; the monitor can show Pending until it runs.

What you configure

An HTTP monitor has a name and an absolute http:// or https:// URL. During beta, requests use GET or HEAD and run every 1, 5, or 15 minutes.

You can set an expected status code, a timeout from 1–30 seconds, an optional latency threshold, and optional custom headers.

Latency threshold

The optional latency threshold sets the maximum acceptable response time in milliseconds. SystemPatrol measures from the start of the check until it receives the final response headers, including DNS lookup, connection setup, and redirects.

For example, with a threshold of 1,200 ms (1.2 seconds) and a 10-second timeout, a response with the expected status passes at 1,200 ms or less. A response with the expected status at 1,500 ms counts as a failed check. Three consecutive failed checks open an incident.

The timeout sets how long the check can wait for a response. The threshold must be a positive whole number of milliseconds below the timeout. For a 10-second timeout, the maximum is 9,999 ms. If you lower the timeout, you may need to lower or clear the threshold before saving. Leave it blank to record response times without failing checks for exceeding a speed target.

How targets stay safe

SystemPatrol validates the hostname and every redirect before connecting. Private, loopback, link-local, metadata, multicast, reserved, and other unsafe addresses are rejected. Redirects are limited, and authorization headers are not forwarded to another origin.

Privacy boundary: Response bodies are bounded during a check and are never stored during beta.

What counts as failure

DNS, connection, timeout, certificate, unexpected-status, and configured latency failures all produce sanitized outcomes. The first two consecutive failures mark a service degraded; the third opens an incident.

Failures are retried at 30-second intervals to confirm an incident. Two consecutive successful checks recover an open incident. Owner emails accompany incident opening and confirmed recovery. See Incidents and recovery.

Review recent results

In Monitors, select Show response times for an HTTP monitor. The five most recent checks show their times, response times, and outcomes. No response means no latency was recorded; the outcome helps distinguish timeout, DNS, connection, certificate, status, or latency failures.

HTTPS and certificates

HTTPS checks validate the certificate chain and hostname. For expiration tracking and warning emails at 30, 14, 7, 3, and 1 day before expiry, add a dedicated SSL certificate monitor.

Custom headers

Header values are encrypted and treated as write-only. After saving a monitor, the application may show configured header names, but it never returns their values.

The dashboard form accepts one secret header name/value pair. Leave both fields blank while editing to retain existing headers. Supplying a pair replaces the configured header set; saved values are not filled back into the form.

If saving or checking fails

Review any field messages, confirm the target is publicly reachable, and check that the method and expected status match your endpoint. Use Edit to change settings. If another session changed the monitor, reload its latest settings before trying again. The workspace limit is 25 monitors across all types.

Back to documentation